SL150 Installation and Setup Guide
15–4
✱
38 CONFIRMATION OF ARMING DING 0
0 = no ding
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button type units or RF keypad
only (ding occurs when the system receives the RF transmission)
Confirmation of arming is ½-second external sounder “ding” when closing
report is sent, or at the end of Exit Delay.
✱
39 POWER UP IN PREVIOUS STATE 1
0 = always power up in a disarmed state
1 = assume the system status prior to power down
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted.
Note: If the previous state was armed AWAY or STAY, the system will not
respond to sensor changes for 1 minute, which allows time for sensors such as
PIRs to stabilize. This means that if a zone is faulted during that
1-minute period, the system will not detect the fault and would power up into
the armed ON AWAY or STAY original state.
UL installations: Must be 1 (power up in previous state)
DIALER
PROGRAMMING
(
✱
40–
✱
50)
✱
40 PABX ACCESS CODE
(See box at left)
| | | | |
Enter up to 6 digits if PABX is needed to access an outside line. If fewer than
6 digits need to be entered, exit by pressing [
✱
]
and next field number
(e.g., 41). To clear entries from field, press
✱
40
✱
.
✱
41 PRIMARY PHONE NO.
(See box at left)
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. If you enter fewer than 20 digits, exit by pressing
[
✱
]
and next field number (e.g., 42). To clear entries from field, press
✱
41
✱
.
NOTE: Backup reporting (in which 8 calls are made to the secondary phone
number if no kissoff is received after 8 attempts to the primary number) is
automatic only if there is a secondary phone number (field
✱
42).
Fields
✱
40,
✱
41,
✱
42:
Enter up to the number
of digits shown. Do not
fill unused spaces.
Enter 0–9,
[#] + 11 for
✱
[#] + 12 for #
[#] + 13 for a pause
(2 seconds)
✱
42 SECONDARY PHONE NO.
(See box at left)
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. If you enter fewer than 20 digits, exit by pressing
[
✱
]
and next field number (e.g., 43). To clear entries from field, press
✱
42
✱
.
See backup reporting note for field
✱
41. If using the pager feature, enter the
pager phone number here.
✱
43 PRIMARY SUBSCRIBER ACCOUNT NO. See box below. F| F| F| F
✱
44 SECONDARY SUBSCRIBER ACCOUNT NO. See box below. F| F| F| F
For Fields
✱
43 and
✱
44:
Enter digits 0–9; [#] +11 = B; [#] +12 = C; [#] +13 = D; [#] +14 = E;
or [#] +15 = F.
If only 3 digits used, exit by pressing [
✱
] and key next field. To clear entries from field, press
✱
43
✱
or
✱
44
✱
.
See separate Programming Form for examples of account number entries.