Security Link SL150 Instrukcja Naprawy Strona 41

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 40
Section 6 - Wireless Expansion
6–5
Some transmitters (e.g., 5802, 5802CP) contain long-life but non-replaceable batteries, and
no battery installation is required. At the end of their life, the complete unit must be replaced
(and a new serial number enrolled by the control).
Button-type transmitters (such as 5801, 5802, 5802CP) should be periodically tested for
battery life.
The 5802MN and 5804 Button Transmitters have replaceable batteries.
Using the Transmitter Sniffer Mode
To use the transmitter Sniffer mode, perform the following steps:
1.
Enter Installer code (4112) + # + 3 on keypad. This initiates a procedure that will verify
that all transmitters have been properly programmed.
2.
The keypad will display all zone numbers of wireless units programmed into the system.
Fault each transmitter in turn, causing each one to send a signal, rather than let
each transmitter send an automatic supervisory signal.
As the system receives a signal from each of the transmitters, the zone number of that
transmitter will disappear from the display. The transmitters may be checked upon
installation, or in an installed system.
3.
After all transmitters have been checked, exit the Sniffer mode by keying 4112 (Installer
code) + OFF.
NOTE: Sniffer mode does not automatically expire. You must manually exit Sniffer mode
by keying [Installer code] + OFF) to return to normal operation.
Use of any RF devices other than a wireless keypad while in Sniffer Mode may cause
unpredictable results.