Section 5 –Wired Zone Expansion
5–3
Programming Wired Expansion Zones
Each zone must be programmed into the system using either the
56 Zone Programming
mode or the
58 Expert Programming mode, either of which assigns characteristics that
define the way the system responds to faults on that zone. Refer to Section 14: Zone
Response Type Definitions and Section 16: Zone Programming for specific instructions
on programming wired expansion zones.
Checkout Procedure for Wired Expansion Zones
Whenever it becomes necessary to disconnect power in order to add a module or keypad, always
disconnect the battery first, then the AC transformer. After installation has been completed,
connect the AC transformer first, then the battery.
After
you
have completed installation and programming of all devices, all expansion zones in
the security system should be checked as follows:
1.
Make certain that all devices and sensors connected to the wired expansion zones are not
in a faulted state. Doors and windows with contacts should be closed, PIRs should be
covered (use a cloth to mask them temporarily, if necessary).
2.
Plug in the AC transformer. With all zones intact (including hardwired zones), the alpha
keypad connected to the system should display:
✱ ✱
SYSTEM READY
✱ ✱
If the following is displayed,
NOT READY Press
to show faults
press
to display the faulted zone(s). Restore any faulted zone(s) as necessary (also
make sure that you have connected a 1000 ohm
EOL resistor
across the terminals of
unused expansion zones on the
4219
or
4229
Module).
When the
SYSTEM
READY
message is displayed, you can proceed to the next step.
3.
Fault and restore every contact or sensor in each expansion zone individually to ensure
that it is being monitored by the system. Each time a zone is faulted, the keypad should
display the number of the faulted zone. When each zone is restored, the
SYSTEM
READY
message should appear again.
You will need to observe the keypad in each zone, as each zone is faulted and restored.
When the proper displays appear on the keypad(s), the wired expansion zones in the
system are functioning properly.
4.
Unplug the AC transformer.
A
CHECK 09
message on the display signifies one of two problems:
Data from the control is not reaching the zone expander module. Check the wiring and DIP
switch settings.
or
The tamper jumper is on in the Expansion Module and the Expansion Module cover is off.